分类: SIEMENS instabus

Switch/dimming actuator 8 x AC 230 V‚ 16 A‚ 1…10 V‚ UL standard N 526E02

2015年4月22日 at 上午11:46分类:SIEMENS instabus

For switching and dimming of eight mutually independent groups (channels) of fluorescent lamps
with dimmable electronic control gear (ECG)
V 8 control voltage outputs 1…10 V DC
V Control power min. 60 OSRAM ECG dynamic each
V 8 switching outputs (relay contacts) for 230 V AC‚ 50/60 Hz‚ 16 A at p.f. = 1
V Each of them for connection of min. 30 OSRAM ECG dynamic for 58 W fluorescent lamps
V Slide switch per relay output for manual operation and switch position indication
V Selection between identical or individual configuration of all channels
V Command objects for each actuator channel for switching on/off‚ dimming brighter/darker and
set/value
V One 1-bit and one 8-bit-status object (switching state and dimming value) per output
V Per channel configurable time-limited activation of the lighting during night mode (base lighting)
V Warning 30 seconds prior to imminent switch off by dimming to 50 % of the previous dimming value
for each channel with time-limited operation
V Switching on or off of a channel by dimming brighter/darker
V Configurable dimming value upon switching on
V Jumping or dimming to a new dimming value
V Configurable dimming time from 0…100%
V Integrated 8 bit scene control and assignment of each output to up to 8 scenes
V Transmission of status objects on request‚ cyclically and/or automatically after changes
V Configurable behaviour on bus voltage failure and recovery
V Bus-powered electronics
V Integrated bus coupling unit‚ bus connection via bus terminal or contact system to data rail
V Modular installation devices for mounting on TH35 EN 60715 mounting rail

Switch/dimming actuator‚ 8 x DALI‚ 8 ECGs per DALI output N 525E01

2015年4月22日 at 上午11:45分类:SIEMENS instabus

8 DALI outputs
V Control capacity for up to 8 DALI-ECGs per DALI output
V Power supplied to the electronics and the DALI outputs through an integrated power supply unit for
230 V AC
V Green LED for status display
V Pushbutton for selecting and switching over 4 DALI outputs respectively between bus and direct mode
V Yellow LED for indicating which 4 DALI outputs the direct mode is activated for
V 1 red LED per DALI output for indicating the circuit state or fault (e.g. lighting medium failure) of the
connected group
V Four pushbutton pairs for switching and dimming of 4 DALI outputs in direct mode‚ functional when
230 V AC is applied (also when no bus voltage is connected and also when bus communication has
not yet been started or is interrupted)
V Selection of identical or individual configuration of all DALI outputs
V Selectable operating mode per DALI output (normal mode‚ 1-level or 2-level time-switch mode)
V Per DALI output with command objects for switching on/off‚ dimming brighter/darker and setting dimming
value
V Per DALI output optionally with up to 4 add-on status objects (circuit state and lighting medium failure‚
dimming value status and DALI status)
V Sending of status objects on request and/or automatically after change
V Per DALI output with add-on object for time-limited switching on of lighting in night mode (cleaning
light)
V Warning approx. 1 minute before imminent switching off‚ by dimming to 50 % of former dimming value
in night or timer mode
V Adjustable switching on and/or off of a channel through dimming brighter/darker‚ dimming value
when switching on‚ actuating or dimming a new dimming value‚ dimming time from 0% to 100%
V Adjustable behavior on bus voltage or mains voltage failure and bus voltage or mains voltage recovery
V Add-on object and integrated 8bit scene control for saving and restoring up to 16 scenes per DALI output
V Integrated bus coupling unit as only half standard bus load
V Bus connection through bus terminal as well as contact system to data rail
V Device for mounting on rail TH35 DIN EN 60715

KNX / DALI Gateway Twin N 141/31

2015年4月22日 at 上午11:44分类:SIEMENS instabus

V Communication via KNX EIB with electronic ballasts (ECG) with a DALI interface
V Two (2) DALI output acc. to IEC 60929‚ each for communication with up to 64 DALI ballasts and at
least 10 sensors
V Integrated power supply with input voltage 110…240 V AC‚ 50…60 Hz or 120…240 V DC for powering
the gateway electronics and DALI output
V Maximum DALI output voltage of 19 V‚ short circuit resistant
V Incorrect voltage detection during commissioning‚ whether incorrect power line is connected to a
DALI output
V LC display for displaying operation mode and error messages
V Pushbutton for switching between bus and direct operating mode
V One pair of push buttons for switching On/Off of all connected DALI ballasts
V One LED per DALI output for status signal of all connected luminaries in direct mode
V Configurable assignment of max. 128 DALI ECG to max. 32 DALI groups‚ exclusive controlled in groups
(switching‚ dimming‚ set dimming value) and feedback for group status and lamp failure
V Configurable behaviour for bus failure (stand-alone mode)
V Control (switching‚ dimming‚ set dimming value) of all connected luminaries together in broad-cast
mode
V Status signal and display of lamp and ECG failure per group and per DALI device
V Possibility to reintegrate defective DALI ECG without software
V One or two level timer
V Integrated scene control for up to 32 scenes
V 16 integrated 2-level-controller for brightness control
V Assignment of DALI ECG to groups and test option for ECG‚ groups and scenes via ETS during commissioning
V Assignment of DALI sensors and test option of sensors via ETS during commissioning
V Integrated bus coupling unit with only half a standard bus load‚ bus connection via bus terminal
V Mounting on DIN rail EN 60715-TH35-7.5

 

KNX / DALI Gateway plus/ Twin plus

2015年4月22日 at 上午11:40分类:SIEMENS instabus

With emergency lighting‚ with sensors
V For communication via KNX EIB with electronic ballasts (ECG) with a DALI interface
V DALI outputs acc. to IEC 62386‚ each for communication with up to 64 DALI ECG and at least 10 sensors
V Integrated power supply with input voltage AC 110-240 V‚ 50-60 Hz or DC 120-240 V for powering
the gateway electronics and DALI output
V Maximum DALI output voltage of 19 V‚ short circuit resistant
V Incorrect voltage detection during commissioning‚ whether incorrect power line is connected to a
DALI output
V LED display for displaying operation mode and error messages
V Pushbutton for switching between bus and direct operating mode
V One pair of push buttons for switching On/Off of all connected DALI ECG
V One LED per DALI output for status signal of all connected luminaries in direct mode
V Configurable assignment of max. 64 DALI ECG per channel to max. 16 DALI groups per channel‚ exclusive
controlled in groups or single (switching‚ dimming‚ set dimming value) and feedback for group
status and lamp failure
V Configurable behaviour for bus failure (stand-alone mode)
V Configurable pre-loaded applications without software (ETS)
V Configurable function burn-in for all ECG via pushbutton or single via object
V Scheduler for day‚ week‚ date and additional astro function
V Control (switching‚ dimming‚ set dimming value) of all connected luminaries together in broadcast
mode
V Status signal and display of lamp and ECG failure per group and per DALI device
V Transformation of dimming commands into a temporary set point adjustment for ECG with integrated
constant light level control and directly connected light level sensor
V One or two level timer
V Up to four integrated one time or cyclical control of repeatable sequences or color effects
V Distinction between self-contained emergency luminaries with one or two DALI devices
V Starting the self-conducted testing of each individual inverter and reporting the test result via bus or
save in a persistent memory with memory space monitoring over object
V Distinction between function test‚ short duration test‚ and long duration test
V Optional configuration of any DALI ECG to dim to a preset dimming value in case of emergency mode
V Locking of switching and dimming commands as well as configuration while emergency mode is activated
V Activation of emergency mode based on a configurable number of failed DALI ECG
V Lock object to elimination of failure messages interruption of ECG during emergency lighting testing
V Inhibit mode for disabling battery mode of self-contained emergency luminaries over pushbutton
V Per channel up to six stand-by-area analysis for activation of switch actuators
V Integrated scene control for up to 16 scenes per channel
V 16 integrated 2-level-controller for brightness control
V 16 integrated constant light level controller for main luminaries group and up to four additional luminaries
groups
V Possible assignment of a CIN to a DALI ECG
V possibility to reintegrate defective DALI ECG without software (ETS)
V Assignment of DALI ECG to groups and test option for ECG‚ groups‚ scenes and effects via ETS during
commissioning
V Assignment of DALI sensors and test option of sensors via ETS during commissioning
V Integrated bus coupling unit with only half a standard bus load‚ bus connection via bus terminal
V Mounting on DIN rail EN 60715-TH35-7.5

Product Title Stock No. Product No.
KNX / DALI Gateway plus‚ 1 channel 5WG1141-1AB03 N 141/03
KNX / DALI Gateway Twin plus‚ 2 channels 5WG1141-1AB21 N 141/21

N527/41 N527/42 N527/51 N527/52 N528/41

2015年4月20日 at 下午12:19分类:SIEMENS instabus

N525

One output for switching and dimming resistive, inductive or capacitive loads

Interface for connecting universal dimmer submodules and with software for controlling up to 5 universal dimmer submodules

Automatic adjustment to leading edge or trailing edge control, depending on the type of load

Integrated power supply unit for the electronics, connected to 230 V AC

A pushbutton on top of the device for switching between bus mode and direct mode and for selecting the device (output A…F) to be switched directly

Two pushbuttons on top of the device for switching and dimming the selected output in direct operating mode

6 bicolor LEDs for indicating the switch status or an error (blinking) in the selected device (output)

Selectable mode for each output (normal mode, one- or two-level timer mode, blinking)

Integrated 8-bit scene control and integration of each output in up to 8 scenes

Integrated bus coupling units, Bus connection via bus terminal

Electronic protection of the output against overload, short circuit and temperature rise

2 subsidiary inputs for 230 V AC (with neutral line as reference potential) for connecting 2 conventional pushbuttons for direct switching and dimming of the output and with selectable additional transmission of these switching and dimming commands via the bus

Max. length of connecting lines on the subsidiary inputs up to 100 m

Determination of switching state by means of the voltage generated in the device

N 527/41 Universal Dimmer, expansions, 20…500 VA, AC 230 V, (R,L,C load)
N 527/42 Universal Dimmer, expansions, 20…500 VA, AC 230 V, for Islanding, (R,L,C load)
N 527/51 Universal Dimmer, expansions, 20…1000 VA, AC 230 V, (R,L,C load)
N 527/52 Universal Dimmer, expansions, 20…1000 VA, AC 230 V, for Islanding, (R,L,C load)
N 528/41 Universal Dimmer, expansions, 20…300 VA, AC 230 V, (R,L,C load)

N 562/11..512/11..513/11 三路开关执行器

2015年4月20日 at 下午12:07分类:SIEMENS instabus

 

up512

3 Floating relay contacts

Rated contact voltage, 230 V AC

Interface for connecting a switching actuator submodule and software for controlling up to 4 switching actuator submodules

Selectable 3-phase switching function (simultaneous switching of 3 outputs)

Direct operation (local operation)

LED for indicating direct operation

LED for indicating the selected device

LED for status indication per output

Selectable 1- to 3-stage fan speed control function

Function for controlling thermo-electrical drives

Integrated 8-bit scene control

Time functions: off delay, on delay, timer mode (automatic stairwell switch), night mode (lighting for cleaning), Warning of impending off

Logical functions: Positively driven operation, Logic function (2 objects), Can be inverted per output (NO contact/NC contact)

Per channel: transmitting status, Operating hours counter with limit monitoring, Switching cycle counter with limit monitoring, Load current recording, Load current monitoring

Power supply for its own electronics and for the electronics of the connected switching actuator submodules via the bus voltage

Bus connection via bus terminal

Description
N 512/11
5WG1512-1AB11
3路16A开关执行器
N 513/11
5WG1513-1AB11
3路20A开关执行器
N 562/11
5WG1562-1AB11
3路10A开关执行器